About Link 1000 Settings
24
Changing the Ambient Temperature Setting
When you have a battery temperature sensor:
If you have a
battery temperature sensor:
1. Leave the default Ambient Temperature setting as is.
2. Turn on Active Temperature Compensation (F16).
(See
page 34.)
When you do not have a battery temperature sensor:
If you
do not have a battery temperature sensor, and if the
temperature around the battery will be substantially different
from 70 °F (21 °C) when the batteries are being charged:
1. Turn the Active Temperature Compensation setting Off.
(See page 34.)
2. Change the Ambient Temperature setting to an
appropriate value.
To change the Ambient Temperature setting:
1. Press and hold
SET until SEL appears.
2. Press
SEL until Func 03 appears.
3. Press
SET to change the temperature in 10 °F increments.
4. Release
SET when the correct temperature appears.
Note: The Active Temperature Compensation setting must be
Off if you are going to change the Ambient Temperature setting.
Otherwise the Link 1000 reports the present battery temperature.