11
© 2001 Xantrex Technology Inc.
P/N 973-0012-01-02 Rev. A 05/01
Connecting the Shunt Board
Remove the fuse from the in-line fuse holder by rotating the fuse holder
cap counterclockwise.
Connect the ring terminal from the fuse holder to the battery’s positive
terminal.
Connect the shunt communications cable into the RJ11 jack on the shunt
board. This cable can be extended up to 100 feet (30 meters).
Replace the fuse in the fuse holder. Replace the fuse holder cap by
pushing and rotating it clockwise.
INVERTER
-
SHUNT
DC FUSE
DISCONNECT
SHUNT IN-LINE FUSE
SHUNT WIRE
3507-00B-F01
J2
J1
INVERTER
RC4/RC8
REMOTE
JACK
GROUND WIRE
(IF RUN IS OVER
100 FEET)
SHUNT JACK
REMOTE JACK
INVERTER ON/OFF
REMOTE CABLE
TC10, TC25, TC50, TC100
(NOT SUPPLIED)
TRACE
METER
(Back View)
BATTERY
+ -
+
Figure 2-10
Circuit Diagram
Figure 2-9
In-line Fuse
In-line Fuse
To battery’s
positive
terminal
To J1
connector on
back of
meter