12 © 2001 Xantrex Technology Inc.
P/N 973-0012-01-02 Rev. A 05/01
Setup
The TM500A is configured at the factory for monitoring a 12 VDC
system. These settings can be changed to meet specific system parameters.
The default settings are:
%
Charge Efficiency 94 %
V
Voltage (full-charge) 14.4 volts DC
A
Amperage DC 35 amps
Ah
Amp Hours 200 Hours
Low-Voltage Indicator 11.2 volts DC
Recharge Reminder OFF
Restoring the Factory Defaults
The factory defaults can be restored to their original settings if desired.
The default values will return to those listed above and are for a 12 VDC
system.
To restore the factory defaults:
1. Set the TM500A into the power saving mode by repeatedly pressing the
SELECT button until the LED display goes blank.
2. Press and hold the RESET button. The display will indicate “ALL”
flashing in the display. Continue to hold the RESET button until the LED
display remains blank.
The factory defaults are now restored.
Figure 3-1
Resetting to Factory Defaults
ALL
Step 2 = ALL then blank
1
2
3.0 CONFIGURATION