Page - 48/100 AE0ZP0EC - AC-0 SSL SENSORED - User Manual
than 10 Hours. (It is used when the controller is replaced with a new one to
keep updated the Total Hours measurement of the truck. It is just enough to
set the OPTION 01 to OPTION 05 with the Final HourMeters of the replaced
Controller).
20) OPTION 04
(MDI-PRC version only). See OPTION 05.
21) OPTION 03
(MDI-PRC version only). See OPTION 05.
22) OPTION 02
(MDI-PRC version only). See OPTION 05.
23) OPTION 01
(MDI-PRC version only). See OPTION 05.
9.4.2 Pump
Using the config menu of the programming console, the user can configure the
following functions.
"SET OPTIONS" SUBMENU
1) TILLER SWITCH
This option handles the input CNB#3. This input opens when the operator
leaves the truck (released). It is connected to a key voltage when the
operator is present. There are two levels:
- HANDLE: CNB#3 is managed as tiller input (no delay when
released).
- SEAT: CNB#3 is managed as seat input (with a delay when
released).
2) MOTION OPTIONS
This option handles the hydraulic steering function activation. It can be set
one of four:
- EXCLUSIVE HYDRO: the hydraulic steering function is activated only if
the pressure switch is active; the pressure switch can be wired on the
pump inverter (input CNB#7) but the request can also arrive from traction
via can-bus.
- OPTION #2: the hydraulic steering function is activated when there is a
running request or the brake pedal is pressed.
- OPTION #3: the hydraulic steering function is activated if one of the two
preceding conditions happens.
- OPTION #4: the hydraulic steering function is activated only if the wired
pressure switch is active (HYDRO STEERING switch on input CNB#7
closed).
3) SET MOTOR TEMP.
- DIGITAL: a digital (ON/OFF) motor thermal sensor is connected to A13
input.
- OPTION #1: an analog motor thermal sensor (KTY83) is connected to
A13 input.
- OPTION #2: an analog motor thermal sensor (KTY84) is connected to
A13 input.
- NONE: no motor thermal sensor switch is connected.
4) HOUR COUNTER
This option specifies the hour counter mode. It can be set one of two: