Page 4 of 24 HydroTap Installation and Operating Instructions - 89650UK - August 2011 v1.02
Hydrotap All-In-One series are able to supply Boiling and Chilled water as well as
Hot and Cold water, all from the same tap.
The ‘AV’ series have their Boiling / Chilled / Hot outlets connected to the
undersink (open vented) unit, Cold outlet conneted to the mains.
The ‘A’ series have their Boiling / Chilled outlets connected to the undersink
(open vented) unit and their Hot and Cold mixer outlets are connected to external
(Mains) Hot water and Cold water supplies.
Product Description
The estimated temperature ranges will be:
Boiling water: 68°C - 98°C
Mixed water: From ambient up to approximately 50°C
Cold water: Ambient.
Chilled water: 5°C - 10°C
Read These Warnings First
Safety
This appliance is not intended for use by persons (Including Children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance
Refrigerant
The HydroTap Chilling unit contains 134A refrigerant under pressure. No part of the
unit should be exposed to a naked flame. Maintenance of the refrigeration unit must
be carried out by an accredited service provider or qualified refrigeration mechanic.
Qualifications
If the power cable is damaged it must be repaired only by a qualified technician. To
avoid hazards, all installation procedures must be carried out by a suitably qualified
tradesperson. The power cable and power outlet must be in a safe visible position for
connection.
Venting
Sometimes steam and / or boiling water may discharge through a vent outlet at the
mouth of the tap. Ensure the tap body is located so the tap outlet safely drains into
the sink bowl area.
NOTE: On startup, the controls take the system through a calibration process which
causes the unit to over-boil for a period of 90 secs. Once this mode is completed the
system reverts back to normal operation.
Lifting
Take care when lifting the HydroTap undersink unit. Some units may exceed
safe lifting limits. If you feel this is beyond your personal capabilities, please seek
assistance with the lift. The weights of the units are marked on the packaging and
given in the table under the heading “Installation Requirements”. Do not lift the unit
by the doors.
Airflow
The ambient temperatures this unit should operate within are 5ºC - 35ºC. Proper
air circulation must be provided. The system will operate satisfactorily only if the
recommended air gaps are provided, these are 65mm min rear clearance and 50mm
side clearance. An air vent is provided with each unit for high usage applications,
this must be installed in the top half of the cupboard door as a matter of course. An
accessory exhaust fan kit is available and should be used to ensure adequate
The power point must be located within
reach of its cable (length 3m). The
appliance must be positioned so that the
power point is accessible.
Hydrotap undersink assembly.
The appliance must be placed in a
horizontal position, as shown above.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zip HydroTap All-In-One BC100/125A and is the answer not in the manual?

Zip HydroTap All-In-One BC100/125A Specifications

General IconGeneral
BrandZip
ModelHydroTap All-In-One BC100/125A
CategoryWater Heater
LanguageEnglish

Related product manuals