Page 16 of 24 HydroTap Installation and Operating Instructions - 89650UK - August 2011 v1.02
HydroTap filter location
External Filter Replacement
These instructions must be read in conjunction with the filter fitting instructions
supplied with the high performance filter kit.
Depending on local water quality conditions and usage, the filter may require
changing anywhere from 1000 Litres to 3000 Litres. You may also need to
replace the filter if you notice unpleasant odours or tastes.
To change the pre-set filter life, scroll through the menu to “External Filter
Life”, press Adjust
>
to reset litre counter. Press Adjust
>
and it asks “are
you sure”. Press Adjust
>
again to lock in the command.
To Change the external filter:
1. Scroll through the screen menu to “Filter Flush Off” this isolates the water
supply.
2. Relieve system pressure by lifting the Hot lever and allowing the water to
run until it shuts off automatically (15 secs.)
3. Remove and replace the spent external filter cartridge as described in the
filter kit instructions. Mop up any spills from the filter head.
4. Scroll through the menu to “External Filter Used ”, press Adjust
>
to reset
the litres. Press Adjust
>
and it asks “are you sure”. Press Adjust
>
again to lock in the command. After approx 10 seconds it will default to the
selected mode.
Internal Filter Replacement
The Zip HydroTap notifies when filter replacement is due. The default setting
is 6000 Ltrs, but this can be set in increments of 1000Ltr from 1000Ltr to
10000Ltrs. When a filter change is due, the Change Filter light will flash white
once a second and remain so until reset. A filter status light is located between
the Red and Blue Lights on the tap head assembly.
Depending on local water quality conditions and usage, the filter may require
changing anywhere from 1000 Ltrs to 10000 Ltrs. You may also need to
replace the filter if you notice unpleasant odours or tastes.
Some water may drip from the filter head (socket) during replacement. Keep a
bucket and towel handy to catch drips and mop up any spills.
To change the Filter:
1. Scroll through the screen menu to “Filter Flush Off” this isolates the water
supply.
2. Open the left door or on the compact model, remove the front cover by
unscrewing the two Phillips headed screws and lift off to expose the filter.
Unravel the Blue filter flush line and place the open end in the bucket.
3. Relieve system pressure via the filter flush stop cock, a quick open and
close will do.
4. Grasp filter cartridge and twist right to left one quarter turn until it stops.
5. Ease cartridge downwards to detach it from the filter head (socket).
6. Do not tilt the cartridge as dirty water may spill from it if tilted.
7. Unpack replacement cartridge and write today’s date where shown on the
label.
8. Avoid touching the filter “O” rings and filter opening as this may cause
bacterial contamination of the cartridge.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zip HydroTap All-In-One BC100/125A and is the answer not in the manual?

Zip HydroTap All-In-One BC100/125A Specifications

General IconGeneral
BrandZip
ModelHydroTap All-In-One BC100/125A
CategoryWater Heater
LanguageEnglish

Related product manuals