ACS/ACC/ACP 601 Frequency Converters A-1
Appendix A – ACS/ACC/ACP 601 Technical Data
IEC Ratings
The IEC ratings for ACS/ACC/ACP 601 with 50 Hz and 60 Hz supplies
are below. ACx = ACS/ACC/ACP. The 690 V series is not available for
ACP 600. Symbols are described below the table.
The table continues on the next page.
Normal Use Heavy-duty Use
ACx 601
Type
Duty Cycle
1/5 min
Duty Cycle
1/5 min
Duty Cycle
1)
2/15 s
Frame
Type
I
2N
4/5min
[A]
I
2Nmax
1/5min
[A]
S
N
[kVA]
P
N
[kW]
P
N
[HP]
I
2hd
4/5min
[A]
I
2hdmax
1/5min
[A]
I
2hd
13/15s
[A]
I
2hdmax
2/15s
[A]
S
hd
[kVA]
P
hd
[kW]
P
hd
[HP]
Three-phase supply voltage 380 V, 400 V or 415 V
ACx 601-0005-3 7.6 8.4 5 3 3 6.2 9.3 6.2 12.4 4 2.2 3 R2
ACx 601-0006-3 11 12 6 4 5 7.6 11 7.6 15.2 5 3 3
ACx 601-0009-3 15 17 9 5.5 7.5 11 17 11 22 6 4 5
ACx 601-0011-3 18 20 11 7.5 10 15 23 15 30 9 5.5 7.5 R3
ACx 601-0016-3 24 26 16 11 15 18 27 18 36 11 7.5 10
ACx 601-0020-3 32 35 20 15 20 24 36 24 48 16 11 15 R4
ACx 601-0025-3 41 45 25 18.5 25 32 48 32 64 20 15 20
ACx 601-0030-3 47 52 30 22 30 41 62 41 82 25 18.5 25 R5
ACx 601-0040-36268403040477147 94302230
ACx 601-0050-3 76 84 50 37 50 62 93 62 124 40 30 40
ACx 601-0060-3 89 98 60 45 60 76 114 76 152 50 37 50 R6
ACx 601-0070-3 112 123 70 55 75 89 134 89 178 60 45 60
ACx 601-0100-3 147 162 100 75 100 112 168 112 224 70 55 75 R7
ACx 601-0120-3 178 196 120 90 125 147 221 147 294 100 75 100
Three-phase supply voltage 380 V, 400 V, 415 V, 440 V, 460 V, 480 V or 500 V
ACx 601-0006-5 7.6 8.4 6 4 5 6.2 9.3 6.2 12.4 5 3 3 R2
ACx 601-0009-5 11 12 9 5.5 7.5 7.6 11 7.6 15.2 6 4 5
ACx 601-0011-5 15 17 11 7.5 10 11 17 11 22 9 5.5 7.5
ACx 601-0016-5 18 20 16 11 10 15 23 15 30 11 7.5 10 R3
ACx 601-0020-5 24 26 20 15 15 18 27 18 36 16 11 10
ACx 601-0025-5 31 34 25 18.5 20 24 36 24 48 20 15 15 R4
ACx 601-0030-5 41 45 30 22 30 31 47 31 62 25 18.5 20
ACx 601-0040-54752403030416241 82302230 R5
ACx 601-0050-55864503740477147 94403030
ACx 601-0060-5 65 72 60 45 50 58 87 58 116 50 37 40
ACx 601-0070-5 84 92 70 55 60 65 98 65 130 60 45 50 R6
ACx 601-0100-5 112 123 100 75 75 84 126 84 168 70 55 60
ACx 601-0120-5 135 149 120 90 100 112 168 112 224 100 75 75 R7
ACx 601-0140-5 164 180 140 110 125 135 203 135 270 120 90 100
Three-phase supply voltage 525 V, 550 V, 575 V, 600 V, 660 V or 690 V
ACx 601-0009-6 7.6 11 9 5.5 7.5 6.2 9 6.2 9 6 4 5.0
R3
ACx 601-0011-6 11 12 11 7.5 10 7.6 11 7.6 11 9 5.5 7.5
ACx 601-0016-6151716111511171117117.510
ACx 601-0020-6202220152015231523161115
ACx 601-0025-625282518.52520302030201520 R4
ACx 601-0030-62831302230253825382518.525
ACx 601-0040-6364040304028422842302230 R5
ACx 601-0050-6444850375036543654403040
ACx 601-0060-6525760456044664466503750 R6
ACx 601-0070-6657270557552785278604560
ACx 601-0100-6 88 97 100 75 100 65 98 65 98 70 55 75 R7
ACx 601-0120-6 105 116 120 90 125 88 132 88 132 100 75 100

Table of Contents

Other manuals for ABB ACS 600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS 600 and is the answer not in the manual?

ABB ACS 600 Specifications

General IconGeneral
BrandABB
ModelACS 600
CategoryControl Unit
LanguageEnglish

Related product manuals