Maintenance
67
Maintenance
What this chapter contains
This chapter contains preventive maintenance instructions.
Safety
WARNING! Read the Safety instructions on the first pages of this manual before
performing any maintenance on the equipment. Ignoring the safety instructions can
cause injury or death.
Maintenance intervals
If installed in an appropriate environment, the drive requires very little maintenance.
This table lists the routine maintenance intervals recommended by ABB.
Heatsink
The heatsink fins pick up dust from the cooling air. The drive runs into
overtemperature warnings and faults if the heatsink is not clean. In a normal
environment, the heatsink should be checked annually, in a dusty environment more
often.
Clean the heatsink as follows (when necessary):
1. Remove the cooling fan (see section Cooling fan).
2. Blow clean compressed air (not humid) from bottom to top and simultaneously
use a vacuum cleaner at the air outlet to trap the dust. Note: If there is a risk of
the dust entering adjoining equipment, perform the cleaning in another room.
3. Replace the cooling fan.
Maintenance Interval Instruction
Capacitor reforming Every year of storage See Capacitors.
Heatsink temperature
check and cleaning
Depends on the dustiness of the environment
(every 6 to 12 months)
See Heatsink.
Cooling fan change Every 6 years if the ambient temperature does
not exceed 40 °C (104 °F).
Every 3 years if the ambient temperature is
higher than 40 °C (104 °F).
See Cooling fan.
Capacitor change Every 10 years See Capacitors.