EasyManuals Logo

ABB WaterMaster User Manual

ABB WaterMaster
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
Sales Service Software
Acknowledgments
Microsoft is a registered trademark of Microsoft Corporation in the United States and / or other countries.
Profibus and Profibus DP are registered trademarks of the Profibus Organization.
Modbus is a registered trademark of the Modbus-IDA organization.
HART is a registered trademark of the HART Communication Foundation.

Other manuals for ABB WaterMaster

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB WaterMaster and is the answer not in the manual?

ABB WaterMaster Specifications

General IconGeneral
Measurement PrincipleElectromagnetic
Protection ClassIP67, IP68
Output Signals4-20 mA, Pulse, Frequency
Liner MaterialPTFE, Polyurethane, Hard Rubber
Electrode MaterialStainless Steel, Hastelloy, Titanium, Platinum
Communication ProtocolsHART, Modbus, Profibus
Power Supply100-240 V AC, 24 V DC
Process ConnectionFlanged, Wafer
Fluid Temperature-40°C to +180°C (depending on liner material)
Process PressureUp to 40 bar
Conductivity≥5 μS/cm
Operating Temperature-20°C to +60°C