Performance Tests
8648D Test Record
Table 8-81. Phase Modulation Distortion Performance Test - Part 1
Frequency
(MHz)
Deviation
(Rad)
Limits (%)
Uncertainty
(%)Lower Measured Upper
0.250 5 0 1 0.26
100 5 0 1 0.26
400 5 0 1 0.26
500 5 0 1 0.26
750 5 0 1 0.26
1000 5 0 1 0.26
Table 8-82. PhaseModulation Distortion Performance Test - Part 2
RF
Frequency
8648D
(MHz)
LO
Frequency
8663A
(MHz)
Input
Frequency
8902A
(MHz)
Deviation
(Rad)
Limits (%)
Uncertainty
(%)
Lower Measured Upper
1500 1501.5 1.5 7 0 1 0.26
2000 2001.5 1.5 7 0 1 0.26
2500 2501.5 1.5 14 0 1 0.26
3200 2500 700 14 0 1 0.26
3800 2500 1300 14 0 1 0.26