EasyManuals Logo
Home>Agilent Technologies>Inverter>E8257D

Agilent Technologies E8257D User Manual

Agilent Technologies E8257D
366 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #144 background imageLoading...
Page #144 background image
134 Agilent N518xA, E8663B, E44x8C, and E82x7D Signal Generators Programming Guide
Programming Examples
RS-232 Programming Interface Examples (ESG/PSG/E8663B Only)
Queries Using HP Basic and RS-232
This example program demonstrates signal generator query commands over RS- 232. Query commands
are of the type *IDN? and are identified by the question mark that follows the mnemonic.
rs232ex2.txt performs the following functions:
• resets the RS- 232 interface
• sets the baud rate to match the signal generator rate
• reads the value of register 4
• queries the signal generator ID
• sets and queries the power level
Start HP Basic, type in the following commands, and then RUN the program:
The following program example is available on the signal generator Documentation CD- ROM as
rs232ex2.txt.
10 !********************************************************************************
20 !
30 ! PROGRAM NAME: rs232ex2.txt
40 !
50 ! PROGRAM DESCRIPTION: In this example, query commands are used to read
60 ! data from the signal generator.
70 !
80 ! Start HP Basic, type in the following code and then RUN the program.
90 !
100 !********************************************************************************
110 !
120 INTEGER Num
130 DIM Str$[200],Str1$[20]
140 CONTROL 9,0;1 ! Resets the RS-232 interface
150 CONTROL 9,3;9600 ! Sets the baud rate to match signal generator rate
160 STATUS 9,4;Stat ! Reads the value of register 4
170 Num=BINAND(Stat,7) ! Gets the AND value
180 CONTROL 9,4;Num ! Sets the parity to NONE
190 OUTPUT 9;"*IDN?" ! Querys the sig gen ID
200 ENTER 9;Str$ ! Reads the ID
210 WAIT 2 ! Waits 2 seconds
220 PRINT "ID =",Str$ ! Prints ID to the screen
230 OUTPUT 9;"POW:AMPL -5 dbm" ! Sets the the power level to -5 dbm
240 OUTPUT 9;"POW?" ! Querys the power level of the sig gen
250 ENTER 9;Str1$ ! Reads the queried value
260 PRINT "Power = ",Str1$ ! Prints the power level to the screen
270 END ! End the program

Table of Contents

Other manuals for Agilent Technologies E8257D