CTP Combitherm
74
•
MN-35948
•
Rev 16
•
10/18
•
Combitherm® CT PROformance™ Series Operator’s Manual
CT PROtouch™ with Automatic Liquid Cleaning
There are ve (5) cleaning levels for liquid cleaning.
• Rinse (20 minutes)
• Light (30 minutes)
• Normal (1 hour 20 minutes)
• Heavy-duty (2 hours 6minutes)
• Heavy-duty PLUS (3 hours 30 minutes)
Use liquid cleaning solution (CE-36457) or Combitherm® liquid
spray cleaner (CE-24750).
Side racks and shelves can remain inside the oven.
NOTICE:
If a power outage happens during a cleaning cycle, the
oven will begin a six (6) minute forced-rinse cycle the
next time it starts.
Make sure the water is turned on and that enough
liquid cleaner is available for the cleaning cycle.
Remove the optional grill grate from the oven interior and
wash separately in hot, soapy water to preserve the special
non-stick coating.
Remove the smoker tray
Remove all solid waste from the drain screen and oven
interior.
Touch the cleaning icon on the home screen. The
cleaning screen
a
displays.
If the cavity temperature is above 150°F (66°C), the Oven Too
Hot warning displays. Open the door and allow the oven to
cool before selecting a cleaning level.
Make sure the liquid cleaner container is lled.
Rinse Light Normal Heavy-duty Heavy-duty PLUS
Select a cleaning level.
Touch the green check mark icon .
The oven shuts down when the cleaning cycle is complete.
Leave the door open when the cleaning cycle is complete to
speed drying.
Remaining
cleaning time
1
CT PROtouch™ with Automatic Liquid Cleaning