6 Pre-Installation Settings AXB-F117 Stealth 1 Camera Controller
Setting zoom, focus, and iris jumpers to servomotor or motor mode
The AXB-F117 supports servomotor (2.5 to 7.5 VDC operating range) and direct-
drive motor (-6 to +6 VDC or -12 to +12 VDC operating range) lens control. Figure 4
shows how to set the jumpers for servomotor mode (S) or motor mode (M). If you
are using a direct-drive lens, refer to the manufacturer’s literature to set the P.
VOLT jumper for 6 or 12 VDC control.
Servomotor and motor voltage jumper settings
Servomotor mode
Motor mode
(-6 to +6 VDC)
Motor mode
(-12 to +12 VDC)
VOLT
FOCUS
IRIS
VOLT
FOCUS
IRIS
VOLT
ZOOM
FOCUS
IRIS
Figure 5 shows the DIP switches and lens control switches accessible on the back
panel.
VOLT
ZOOM
AXlink
Figure 4
Servomotor and motor
voltage jumper settings
Figure 5
DIP switches and control
mode/voltage switches