7
OPERATIONAL CURVES
Conditions: inlet water temperature 15°C, set water temperature 55°C, air medium humidity 87% - Heating up Energy based on
air temperature (EN 255-3).
80 LITRES Mode: GREEN
Tair [°C] tH-Heating-up time [h:mm:ss] EH-Heating-up energy [kWh] COPt Qpr
-5 4.40.50 1,83 1,9 0,456
2 3.46.17 1,54 2,3 0,456
7 2.44.26 1,19 2,9 0,456
20 2.02.54 0,96 3,5 0,456
30 1.37.35 0,82 4,1 0,456
42 1.36.00 0,80 4,1 0,456
Max. amount of hot water in a single intake
V40 with water at 55°C 95 l (ratio 1,2)
V40 with water at 62°C 113 l (ratio 1,41)