EasyManuals Logo
Home>Atlas Copco>Air Compressor>SF 17+

Atlas Copco SF 17+ User Manual

Atlas Copco SF 17+
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Typical Main screen (2 value lines)
To go to the Menu screen, select action button Menu (1) by means of the Scroll keys and
press the Enter key.
Following screen appears:
Text on image
(1) Menu (2) Regulation
The menu screen shows a number of icons. Each icon indicates a menu item. By default,
the Regulation icon is selected. The status bar shows the name of the menu that
corresponds with the selected icon.
Use the Scroll keys to select the required icon (see further). Pressing the Escape key
returns to the Main screen.
3.6 Shutdown warning
Description
A shutdown warning will appear in the event of:
Too high element temperature
Too high ambient temperature
Too high dew point temperature (on compressors with integrated refrigerant dryer)
High element temperature
When a compressor element temperature exceeds the warning level, the element stops during a
Minimum Stop Time . It will be restarted automatically after this time has elapsed and if the
temperature is below this limit.
Instruction book
2920 7140 52 35

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco SF 17+ and is the answer not in the manual?

Atlas Copco SF 17+ Specifications

General IconGeneral
BrandAtlas Copco
ModelSF 17+
CategoryAir Compressor
LanguageEnglish

Related product manuals