Typical Main screen (2 value lines)
• To go to the Menu screen, select action button Menu (1) by means of the Scroll keys and
press the Enter key.
Following screen appears:
Text on image
(1) Menu (2) Regulation
• The menu screen shows a number of icons. Each icon indicates a menu item. By default,
the Regulation icon is selected. The status bar shows the name of the menu that
corresponds with the selected icon.
•
Use the Scroll keys to select the required icon (see further). Pressing the Escape key
returns to the Main screen.
3.6 Shutdown warning
Description
A shutdown warning will appear in the event of:
• Too high element temperature
• Too high ambient temperature
• Too high dew point temperature (on compressors with integrated refrigerant dryer)
High element temperature
When a compressor element temperature exceeds the warning level, the element stops during a
Minimum Stop Time . It will be restarted automatically after this time has elapsed and if the
temperature is below this limit.