5.6 Stopping
Control panel
Description
Press stop button (6).
Close the air outlet valve.
Emergency stopping
To stop the unit immediately, press the emergency stop button. Warning sign (2) starts
blinking.
Close the air outlet valve.
After remedying the trouble, unlock the emergency stop button by pulling it out or by turning
it to the right (depending on the model of the switch).
5.7 Taking out of operation
Procedure
At the end of the service life of the unit, proceed as follows:
Step Action
1 Close the air outlet valve, stop the unit and press the emergency stop button.
2 Switch off the voltage and disconnect the unit from the mains.
3 Shut off and depressurize the part of the air net which is connected to the outlet valve.
4 Disconnect the unit air outlet pipe from the air net.