3 Technical specifications
3.1 Homologations
3.1.1 Certifications
Electrical Conformity / CE Marking
This product complies with the requirements of the following European
Directives and Standards:
Low Voltage Directive 2006/95/EC.
Relevant standard: EN 60335-1
Electromagnetic Compatibility Directive 2004/108/EC
Relevant standards: EN 55014-1:2006 + A1 + A2 / EN 55014–2:2006 +
A1 + A2
3.1.2 2014/68/UE Directive
This product conforms to the requirements of European Directive
2014/68/UE, article 4, paragraph 3, on pressure equipment.
3.1.3 Factory test
Before leaving the factory, each appliance is tested for the following:
Water tightness
Air tightness
Electrical safety.
3.2
Technical data
3.2.1 Specifications for the domestic hot water sensor
Important
Tolerance: +/- 5 Ohm
Tab.2 Domestic hot water sensor
Temperature (in °C) 10 20 25 30 40 50 60 70 80
Resistance (in ohms) 19691 12474 10000 8080 5372 3661 2536 1794 1290
3.2.2
Appliance specifications
Tab.3 General specifications
Model Unit SPC 200 SPC 300 SPC 300S
Heating time (15-51 °C) hours 5 7 7
Qpr kWh/24h 0.73 0.67 0.75
V40 litres 240 357 358
Capacity litres 215 270 260
Weight (empty) kg 92 105 123
R-134a refrigerant kg 1.45 1.45 1.45
R-134a refrigerant
(1)
tCO
2
e 2.075 2.075 2.075
Output (heat pump) with air
temperature = 15 °C
W 1700 1700 1700
Immersion heater output W 1800 1800 1800
Operating pressure MPa (bar) 1.0 (10) 1.0 (10) 1.0 (10)
Power supply voltage V 230 230 230
3 Technical specifications
12 7734712 - v01 - 22052019