1. To change the operating mode, press the MODE key several times,
until the symbol corresponding to the required operating mode is
shown on the display.
Tab.13
Display Operating mode Description
Automatic or comfort Comfort program active
The production of domestic hot water is ensured by the heat pump and, if neces
sary, by the electrical back-up (+ hydraulic back-up for the SPC 300S model).
If insufficient domestic hot water has been produced by the compressor at the
end of an adjustable time delay (factory setting: 5 hours - parameter ), the
back-ups start.
Eco Reduced program active
The production of domestic hot water is ensured by the heat pump only.
After the compressor stops, the display showing the available quantity of domes
tic hot water may not be full ( ).
Boost Forced operation active
The production of domestic hot water is ensured by the heat pump and the back-
up simultaneously for a defined period (factory setting: 6 hours).
days Holiday Holiday period
Production of domestic hot water is stopped.
The domestic hot water temperature remains at 10 °C.
6.6 Reading out measured values
6.6.1 Measurements menu
1. Press the MENU key once.
The menu is displayed.
2. Press the MODE key to go into the Measurements menu.
The menu is displayed.
Fig.26
C003493-B
1
4
3
4
1
2
Fig.27
C003206-D
1x
2x
3x
.
.
.
1
4
3
4
1
2
MENUMODE
6 Commissioning
36 7734712 - v01 - 22052019