- Press the heating function's "-" button: the burner's
power level will be set to minimum. Turn the adjust-
ment screw (2) to adjust the combustion, and bring
the CO
2 to the values indicated in the table
POWER X 35 R.S.I.
2
CO
2
+
Fig. 45
POWER X 50 / 50 R.S.I.
-
POWER X 50 DEP R.S.I.
CO
2
+
2
Fig. 46
The following table shows the CO2 values for Methane and
LPG, at the maximum and minimum power levels.
Natural gas LPG
Maximum output 9.0 - 9.2 10.5-11.0
Minimum output 9.0 - 9.2 10.5-11.0
4.7 Changing Gas - Methane-LPG
transformation
The boiler is predisposed for use with methane gas.
This predisposition can only be modified using the transfor-
mation kit supplied by the manufacturer.
The modification can only be performed by the authorized
Technical Assistance Centre, using the following proce-
dure.
- Shut off the boiler's electrical power supply and close
the gas valve.
b
The electrical power supply must be disconnected
using the omnipolar switch, which must be installed
outside the boiler during the appliance's installation
phase.
b
While shutting off the boiler using the ON/OFF button
on the control panel renders the appliance inactive,
its components are nevertheless still receiving elec-
trical power.
- Insert the appropriate "A" diaphragm
POWER X 35 R.S.I.
A
Fig. 47
POWER X 50 / 50 R.S.I.
-
POWER X 50 DEP R.S.I.
A
Fig. 48
- Perform the proper setting of the P0 jumper (see J3 in
Fig. 8), as indicated in the following table, based on
the relative gas
Natural gas LPG
P0
P0
- Reactivate the electrical power supply and the gas
supply, and turn on the boiler
- Perform the adjustment as described in the section "
Adjustments".

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beretta Power X 50 DEP R.S.I. and is the answer not in the manual?

Beretta Power X 50 DEP R.S.I. Specifications

General IconGeneral
BrandBeretta
ModelPower X 50 DEP R.S.I.
CategoryBoiler
LanguageEnglish

Related product manuals