<Automatic> button
! Observe the ACS 611 menu prompting.
1. Call up start screen.
2. Press <Automatic>.
SELECT PORTS?
1 HP & LP PORTS
2 HP PORT
3 LP PORT
3. Select <1>,<2> or <3>; confirm with E.
SET VACUUM TIMEis displayed.
4. Set duration of vacuum generation with <0 – 9>,
zv and confirm with E.
CHARGING UV DYE?
1 - YES
2 - NO
5. Select <1> or <2>; confirm with E.
CHARGING OIL?
1 - YES
2 - NO
i With <1> the following is shown:
INTRODUCE EXTRA OIL
The added fresh oil quantity (added oil quantity,
see glossary) must be set with <0 – 9>, z v and
confirmed with E.
6. Select <1> or <2> and confirm with E.
SET REFRIGERANT CHARGE is displayed.
7. Enter refrigerant quantity (R134a) with <0 – 9>,
zv and confirm with E.
"ACS 611 performs "Automatic service".
i Return with <Stop>.
7.5 Processing
!
Observe the ACS 611 menu prompting.
1. Call up start screen.
2. Press <MENU>.
3. Select <Processing> with o u and confirm with E.
i The processing duration is limited to 60 minutes
and stops automatically after the internal circuit has
been drained.
i Return with <Stop>.