9
ENG
easy/easy compact/easy split +030220791 - rel. 3.2 - 13.07.2010
1.3 Main di erences between easy, easy
compact and easy split
Unlike the easy and easy compact models, the easy split models feature
a separate terminal and power board. There are also other di erences,
such as the auxiliary multifunction relay for managing the light output
or a second compressor, and new software functions. The table below
highlights the di erences and indicates the page showing the related
explanation.
• connection cable between terminal and power board (easy split only).
Available in di erent lengths (PEOPZC1500=1.5 m, PEOPZC3000=3.0
m, PEOPZC5000=5.0 m).
1.6 De nitions
Continuous cycle: function that runs the compressor for the set time.
Defrost: function that controls the defrost of the evaporator.
Duty setting: safety function that in the event of control probe faults
starts the compressor at set time intervals.
easy: trademark of the PJEZ(S, X, Y, C, M)* thermostats.
easy compact: more compact and economical version of the easy.
Available in models PJEZ(S, M)*.
easy split: version with separate terminal and power board. Versions
available with (PJEZ*8R***) or without (PJEZ*8I***) RTC, and the power
board can be supplied with (PJEZ*8**5*) or without (PJEZ*8**4*) plastic
case.
topic
easy, easy
compact
easy split
easy split
parameter
page
type of probes connectable (selectable by parameter, easy split only) NTC, PTC NTC, NTC-HT /P 9
dedicated relay for the light output NO YES H1=4 29
light on/o from the keypad defrost only YES H1=4 16
probe display rate function NO YES /3 17
curtain switch (night-time operation) with light management NO YES A4=4 24
light not managed/ managed with door switch and evaporator fan o NO YES A4=7, 10 25
light not managed/ managed with door switch and evaporator fan and compressor o NO YES A4=8, 11 25
door open/closed management NO YES Ado 25
second compressor output in parallel with dedicated relay NO YES H1=5 29
second compressor output with two step control with or without rotation NO YES H1=7/6 29
second compressor delay NO YES c11 19
fan management with compressor o NO YES F2=2, F4, F5 27
night-time operation with light management NO YES A4=4, H1=4 24
year, month, day of month setting NO YES YEr, MOn, dMO 28
disable high temperature alarm when starting NO YES - 31
maintenance request signal (SrC) NO YES HMP, HMd, HMr 30
Table 1.c
1.4 NTC and PTC probes
All easy and easy compact models use PTC and NTC probes conforming
to the CAREL standard, with resistance values of 985 at 25°C for the
PTC, and 10 k for the NTC. The type of probe installable depends on
the model (order code). The easy split models, on the other hand, only
use NTC and high temperature NTC probes (50 K at 25°C), selected by
parameter. Below are some codes of the more common CAREL.
code description operating
range
index of
protection
NTC***HP00 NTC probe, 6x15 mm
bulb, plastic
-50T50°C IP67
NTC***HT00 High temp. NTC probe,
5x20 bulb mm, polyester
0T120 °C
(max 150 °C for
3000 h)
IP55
NTC***WP00 NTC probe , 6x40 mm
bulb, metal
-50T100°C IP67
PTC***W000 PTC probe, 6x40 mm
bulb, metal, 1.5 m long
-50T100°C IP67
Table 1.d
1.5 Accessories
• CAREL IROPZKEY* programming key (for duplicating the parameters);
• CAREL IROPZ485S0 RS485 converter (for the RS485 supervisory
network).
• CAREL USB/RS485 converter CVSTDUMOR0 to interface a RS485
network to a personal computer via the USB port;
• VPM, program downloadable from http://ksa.carel.com. This tool,
running on a computer, can be used to commission the controller,
program the parameters and update the rmware;
• COM TOOL, program downloadable from http://ksa.carel.com. This tool
can be used to program the controller from any PC, save the di erent
con gurations in les that can be recalled during nal programming,
create custom sets of parameters for rapid programming and con gure
the di erent users with password protected access pro les. Connection
to the PC requires the USB/RS485 converter code CVSTDUMOR0;