63
32 User Wave Data
This is the actual wave that is sent along with each wave parameter.
System Exclusive Format
33 User DSP Parameter Set
System Exclusive Format
Field Value
01 SYSEX F0
02 MAN 44
03 MOD 11,02
04 dev Either 00 to 1F, or 7F
05 act 04(HDS), 05(HDR), 07(Control)
06 cat Wave Data = 08
07 prm 00-7F
08 ilen/dlen See "IV This Model's System Exclusive Messages".
09 ps Indicates the wave number being transferred.
For details, see "40 About Parameter Set (PS) numbers".
10 index See "IV This Model's System Exclusive Messages".
11 data See "IV This Model's System Exclusive Messages".
12 sum See "IV This Model's System Exclusive Messages".
13 EOX F7
Field Value
01 SYSEX F0
02 MAN 44
03 MOD 11,02
04 dev Either 00 to 1F, or 7F
05 act 04(HDS), 05(HDR), 07(Control)
06 cat DSP = 09
07 prm 00-7F
08 ilen/dlen See "IV This Model's System Exclusive Messages".
09 ps Indicates the DSP number being transferred.
For details, see "40 About Parameter Set (PS) numbers".
10 index See "IV This Model's System Exclusive Messages".
11 data See "IV This Model's System Exclusive Messages".
12 sum See "IV This Model's System Exclusive Messages".
13 EOX F7