CHAPTER 6
Verify Chassis Installation
Verify Device Installation, on page 99
Verify Device Installation
After installing the Cisco NCS 5700 Router, you can use the show commands to verify the installation and
configuration. If any issue is detected, take corrective action before making further configurations.
DescriptionCommand
Displays information about the field replaceable units
(FRUs), including product IDs, serial numbers, and
version IDs.
show inventory
Displays the operational status of the nodeshow platform
Displays the version of the router.show version
Displays all environment-related router information.admin show environment
Displays temperature readings for card temperature
sensors. Each system controller, route processor, line
show environment temperature
card, and fabric card has temperature sensors with
two thresholds:
Minor temperature threshold: when a minor
threshold is exceeded, a minor alarm occurs and
the following actions occur for all four sensors:
System messages displayed
SNMP notifications (if configured) sent
Log environmental alarm event triggered
(can be reviewed by running the show alarm
command).
Major temperature threshold: when a major
threshold is exceeded, a major alarm occurs and
the following actions occur:
Hardware Installation Guide for Cisco NCS 5700 Series Fixed-Port Routers
99

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS-57C3-MOD-SYS and is the answer not in the manual?

Cisco NCS-57C3-MOD-SYS Specifications

General IconGeneral
BrandCisco
ModelNCS-57C3-MOD-SYS
CategoryNetwork Router
LanguageEnglish

Related product manuals