Page #19 background imageLoading...
Page #19 background image
4
Dimensions
AX1000T
Series
AX1000T
Actuator
Dimensions
AX1022T
AX1045T
(Option)
For mounting dial plate
(Cable bending range)
(Including hollow section)
Rotating section
Mounting base
6-Φ7 (straight)
6-M6 depth 11 (straight)
P.
C
.D.140
P.C.D.70
6-M6 depth 9 (straight)
P.C.D.180
185
78
19.5
Rotating section
(Including hollow section)
Φ40h7
Φ25
Φ22
Φ24
Φ120h7
Φ200
A
23
22
91
103
5
12
8
11
55
5
102
22
Φ160
Φ152
Φ120
Φ85
12
(Option)
Φ6H7 depth 8
35
15°
0.04 A
45°
P.
C
.D.140
6-M6 depth 9 (straight)
Not available if the optional base is installed.
Φ6H7 depth 8 (option)
0.04
B
70
(32)
(27)
(Option)
For mounting dial plate
(Cable bending range)
(Including hollow section)
Rotating section
Mounting base
6-Φ7 (straight)
6-M6 depth 11 (straight)
P.C
.D
.140
P.C.D.70
6-M6 depth 9 (straight)
P.C.D.180
185
78
19.5
Φ160
A
Φ152
Φ120
Φ85
Φ25
Φ22
Φ24
Φ120h7
Φ200
102
22
Φ40h7
Rotating section
(Including hollow section)
23
8
126
138
55
11
12
12
22
5
5
(Option)
Φ6H7 depth 8
35
15°
0.04 A
45°
P.
C
.D.140
6-M6 depth 9 (straight)
Not available if the optional base is installed.
Φ6H7 depth 8 (option)
0.04
B
70
(32)
(27)
Note 1) The origin of the actuator may differ from the dimensions shown above.
Origin can be configured randomly using the origin offset function.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CKD AX1000T Series and is the answer not in the manual?

CKD AX1000T Series Specifications

General IconGeneral
BrandCKD
ModelAX1000T Series
CategoryController
LanguageEnglish

Related product manuals