Installation and maintenance instructions
EN
SETTING STANDARD PARAMETERS –P-
PARAMETER FUNCTION STATE
P1
Water ll normal / cold
1
P2
Normal wash / with pre-rinse
0
P3
Heating commutated/simultaneous
0
P4
N° wash pumps 1 / 2
1
P5
Normal / cold cycle boiler temperature management
1
P6
Startup management on the temperature tank not active / active
0
P7
Dumper machines: partial / total discharge
0
P8
Automatic recognition of the racks not active / active
0
Cr
Autonomy of the softener (n° cycles)
0……999
Ct
Cycle counter
1…65536
STANDARD SETTINGS OF T AND L PARAMETERS
PARAMETERS FUNCTIONS
SHORT
CYCLE
(H9a)
MEDIUM
CYCLE
(H9b)
LONG
CYCLE
(H9c)
INTENSIVE
CYCLE
(H9d)
T1 TANK TEMPERATURE 55°C 55°C 55°C 55°C
T2 RINSE TEMPERATURE 85°C 85°C 85°C 85°C
L1
WASH TIME 80sec. 200sec. 320sec. 565sec.
L2
PAUSE TIME 10sec. 10sec. 10sec. 10sec.
L3
RINSE TIME 18sec. 18sec. 18sec. 18sec.
L4
OSMOSIS RINSE TIME
(Optional)
15 sec. 15 sec. 15 sec. 15 sec.
L5
DRAIN TIME 0 sec. 0 sec. 0 sec. 0 sec.
L6
EXTRA TIME
0-140sec.
10 sec. 10 sec. 10 sec. 10 sec.
44