EasyManuals Logo
Home>Compac>Control Unit>C5000

Compac C5000 User Manual

Default Icon
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
11.
K-Factor Settings
K-Factor Settings
A summary of the K-Factor settings can be seen below. Information on these settings and how
to change them can be found on the following pages.
Setting
Price display
Litres display
Dispenser settings
C-A or C-B
*******
Meter ID
ID-A or id-b
******
Temperature calibration
E-a or e-b
**.*
Density calibration
D15-a or d15-b
***.*
Maximum flow
QA **** or qb ****
K-Factor
FA or FB
***.****
Configuration code
C
*******
Comms
Cc
****
Solenoid delay
5da *** or 5db ***
Preset cutoff
Pca *.** or pcb *.**
Preset rounding
Prla*.** or prlb*.**
prxa*.** or prxb*.**
Flow time out
n-a *** or n-b ***
Using the Dispenser Menus
When changing settings on the dispenser, pressing the K-Factor switch in quick succession
cycles between the options available. The location of this switch can be found on page 7. Each
press of the button will cycle between the digits. When going through the menus, each menu
will cycle through the digits twice for ease of operation.
When a digit is flashing, hold down the relevant switch to increment this digit. Release the
switch on the desired value.
The system timeout is 10 seconds.

Other manuals for Compac C5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compac C5000 and is the answer not in the manual?

Compac C5000 Specifications

General IconGeneral
BrandCompac
ModelC5000
CategoryControl Unit
LanguageEnglish

Related product manuals