29.
Parameter Settings
Assigning a number to slave display
Slave display numbers can be set with dip switch 2 and 3 on the slave display board. Use the
following table as a guide to configure the slave displays
Slave Display
Switch 1
Switch 2
Switch 3
1
OFF
OFF
OFF
2
OFF
OFF
ON
3
OFF
ON
OFF
4
OFF
ON
ON
CAUTION : Make sure the device is powered off before attempting to change the dip switches
Changing the Custom Display Configuration
The custom display configuration can be used to show additional information on the unit price
display. The additional information that can be shown includes the density, temperature,
flowrate, and reset batch. This can be configured with the dc setting. Each digit corresponds to
a custom display option. Setting a digit to 1, as opposed to 0, enables the custom display. The
digits represent the following options:
Digit 1: Reset batch
Digit 2: Temperature display
Digit 3: Density display
Digit 4: Flowrate display
For example, the following code would enable temperature and flowrate to be shown on the
custom display.
Dc 0101