Standard Mode
In standard mode, the main display will show:
• Top row: Transaction total in dollars
• Second row: Compensated litres for LPG, or uncompensated litres for non-LPG,
dispensed by default, but can be changed in Dispenser Settings
And the unit price window will display the price per litre.
Purge Mode
Test mode can be used for all calibrated runs with the exception of vapour tests. When in purge
mode, the following is displayed on the main display:
• Top row: purge
• Second row: Uncompensated litres dispensed
If the meter setting is set to V50 meter, the unit price window will alternate between showing
temperature and density at 15 °C. If the density is outside of the compensation range, then the
observed density will be displayed. This information is obtained from the V50 meter.
If the meter settings are set to encoder meter, the unit price display will show flowrate.
In purge mode, all display suppression is turned off.
Preset Options
A preset in dollars or litres can be set. Before a transaction, type in a desired preset value. There
are three options for setting a preset:
• Dollars – the preset will be shown in the top row of the main display
• Litres – the preset will be shown in the bottom row of the main display
• Switchable – The preset can be switched between dollars and litres by holding ‘#’ for
three seconds when not in a transaction.
Presets can still be entered during a transaction, as long as flow has not started. Enter a preset
by using the keypad. Pressing # will clear a preset. As soon as flow starts, the preset can not be
changed, however, pressing the # key during the transaction will display the preset amount.
Pressing # after a transaction will recall the last preset. This will then be used for the next
transaction, if it is displayed when the nozzle is picked up. This is useful for multiple
transactions in a row requiring the same preset.
Presets entered must be larger than the MMQ. If the MMQ is large, when entering a preset after
lifting the nozzle, the MMQ will automatically show up. Continue entering the desired preset to
override this. If entering a preset before lifting the nozzle, and a value below the MMQ is
entered, an error code will be returned.