6 x Parameter settings
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
47
6.10 Rotary switch setting: Info
Parameter Description Access Setting range
Min / Max
Factory
setting
Incre-
ment
BE HF
Overview Display of different current operating data (see chap. 3.4.1). S S - - -
Water Pressure The current water pressure is displayed in bar. S S 0 - 4 bar - 0.1 bar
T-HS The current flow temperature of the heat generator ( t
V1
) is displayed in °C. S S 0 - 100 °C - 1 °C
T-HS Setpoint The current target temperature of the heat generator is displayed in °C. S S 0 - 90 °C - 0.1 °C
T-Outside The current outside temperature is displayed in °C. S S -39 - 50 °C 0.1 °C
T-DHW The current temperature of the hot water storage tank is displayed in °C. If no hot water function
is activated, "- - -" is displayed.
S S 0 - 100 °C - 0.1 °C
T-DHW Setpoint The current target temperature for hot water generation is displayed in °C. If no hot water function
is activated, "- - -" is displayed. Here, the current target value is always the maximum value of all
requirements relevant for this hot water circuit.
S S 10 - 70 °C - 0.1 °C
T-Return The current T-Return of the heat generator is displayed in °C. If no respective sensor is connect-
ed to the heat generator, "- - -" is displayed.
S S 0 - 100 °C - 0.1 °C
Flow Rate The filtered value of the current volume flow is displayed. S S 0 - 5100 l/h - l/h
T-HC The temperature of the direct heating circuit ( t
V2
is displayed with active heating support, oth-
erwise t
V1
) in °C.
S S 0 - 100 °C - 0.1 °C
T-HC Setpoint The (flow) target temperature of the direct heating circuit is displayed in °C. S S 0 - 90 °C - 0.1 °C
T-Exhaust The current flue gas temperature of the heat generator is displayed in °C. S S -39 - 300 °C - 0.1 °C
Burner The current status of the heat generator is displayed (flame signal). S S Off
On
- -
Gas Valve 1 The current status of the oil valve of the heat generator is displayed.
Displayed value (always "Off") not relevant!
Information on the burner status, see "Overview" Info parameter
S S Off
On
- -
Position 3UV The current flow direction in the 3-way switching valve is displayed
CH: Room heating
DHW: Hot water generation
S S CH
DHW
- -
Status HS pump The current status of the internal circulation pump of the heat generator is displayed. S S Off
On
- -
Burner Starts Sum of all starts of the burner.
The data is updated every 20 min.
S S - - 1
Control Deviation Current control deviation (target value – actual value) of the T-HS of the heat generator. S S - - 1 K
Desired Output Currently required target performance of the burner in %. A floating display is only possible for
modulating heat generators. Depending on the setting and current status of the heat generator
(set minimum performance, start phase), the current actual value of the performance can signif
-
icantly deviate from the target value.
A single-stage switching burner is only requested with the target values 0 % and 100 %, a two-
stage switching burner only with the target values 0
%, 50 % and 100 %.
S S - - 1 %
HS type The configured type of the heat generator is displayed. S S - - -
Runtime Pump The runtime of the internal heating circulation pump is displayed in h. S S - - 1 h
Burner Oper Time Total runtime of the burner in hours.
The data is updated every 20 min.
S S - - 1 h
Mixer Position Only 5xx: The current position of the 3-way mixing valve 3UV DHW in % is displayed. S S - - 1 %
Qch The quantity of heat of the heat generator for the heating operation is displayed in kWh. S S - - kWh
QWP The entire quantity of heat of the heat generator is displayed in kWh. S S - - kWh
Qdhw The quantity of heat of the heat generator for hot water generation is displayed in kWh. S S - - kWh
Sw Nr B1/U1 The software and version of the operating unit are displayed. S S - - -
Sw Nr Controller The software number and version of the control PCB are displayed. S S - - -
Sw Nr FA The software number and version of the firing unit are displayed. S S - - -
Tab. 6-14 Parameters in the "Info" rotary switch setting
Depending on the device type, the system configuration
and the version of the device software, individual infor
-
mation parameters listed in tab. 6-14 cannot be dis-
played or are displayed at another parameter level.