7 x Errors and faults
7.2 Emergency operation
For faults or incorrect settings of the electronic control unit,
emergency heating operation (manual operation) can be
maintained.
Please observe the supplementary notes for this in the instal-
lation manual of the heat generator.
1. Push the Exit button for at least 5 s.
The "Special Level" menu is displayed.
2. Use the rotary button to select the "Manual Operation" level.
Temperature scale, target and target T-HS are displayed.
3. Use the rotary button to set the target T-HS.
The Daikin heat generator works manually at the target T-
HS.
4. Cancellation and jump back by pushing the Exit button again.
Fig. 7-4 Software information of the control unit components
Info
Overview
Water Pressure
T-HS
Sw Nr B1/U1
Sw Nr FA
Info
Sw Nr B1/U1
Sw Nr Controller
Sw Nr FA
Info
Sw Nr B1/U1
Sw Nr mixing valve
Sw Nr Controller