SiUS091133 Outdoor Unit: RXS09/12LVJU
Removal Procedure 270
4.2 Removal of Electrical Box
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1
Disconnect the
connector for the
overload protector
[S40].
Preparation
Remove the outer panels and
disconnect the connector for the
fan motor according to the
“Removal of Outer Panels / Fan
Motor”.
2
Disconnect the
connector for the four-
way valve coil [S80].
3
Disconnect the 2
connectors for the
reactor.
When reassembling, you can
connect the 2 harnesses in
either way regardless of the
color.
[S40]
(R16924)
[S80]
(R16925)
(R16926)

Table of Contents