SiBE18-821_C Indoor Unit Control (RA Models)
Function 117
7.14 Other Functions
7.14.1 Hot-Start Function
In order to prevent the cold air blast that normally comes when heating operation is started, the
temperature of the indoor heat exchanger is detected, and either the airflow is stopped or is
made very weak thereby carrying out comfortable heating of the room.
*The cold air blast is also prevented using a similar control when the defrosting operation is
started or when the thermostat is turned ON.
7.14.2 Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal
receiving sound.
7.14.3 Indoor Unit ON/OFF Button
An ON/OFF button is provided on the display of the unit.
îš„
Press this button once to start operation. Press once again to stop it.
îš„
This button is useful when the remote controller is missing or the battery has run out.
îš„
The operation mode refers to the following table.
îš„
In the case of multi system operation, there are times when the unit does not activate with
this button.
ex. Wall mounted type G-series 20-50 class
7.14.4 Titanium Apatite Photocatalytic Air-Purifying Filter
This filter combines the Air-Purifying Filter and Titanium Apatite Photocatalytic Deodorizing
Filter as a single highly effective filter. The filter traps microscopic particles, decompose odors
and even deactivates bacteria and viruses. It lasts for 3 years without replacement if washed
about once every 6 months.
7.14.5 Photocatalytic Deodorizing Filter
The photocatalytic deodorizing filter powerfully decomposes odor of tobacco, pet, etc. The
deodorizing power is regenerated simply by being exposed to the sunshine. It is recommended
to dry the filter in the sun for about 6 hours (after vacuuming the filter) every 6 months.
7.14.6 Air-Purifying Filter
The air-purifying filter collects tobacco smoke, pollen, etc. with electrostatic agency. This filter
includes a deodorizing active carbon filter that removes minute particles of odor. Replace the
air-purifying filter every 3 months.
Mode Temperature setting Airflow rate
AUTO 25°C Automatic
(R8302)
ON/OFF button

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Super Multi Plus E-Series RMXS112E8V1B and is the answer not in the manual?

Daikin Super Multi Plus E-Series RMXS112E8V1B Specifications

General IconGeneral
BrandDaikin
ModelSuper Multi Plus E-Series RMXS112E8V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals