PVG 32 pressure setting
PVG 32 pressure setting (LS connection)
P109140
C
LS
A
C
C
LS
B
C
C
LS
C
T
6[0.24]
360º~1450 psi
360º~100 bar
C-C
4[0.16]
360º~1740 psi
360º~120 bar
T
C-C
Relief valve availability
Valve Prior to week 40/2003 Between week 40/2003 and week
2/2012
After week 2/2012
Relief valve 1 X X
Relief valve 2 X X
"X" denotes availability.
Rated pressure
Module Rated pressure
PVG 32 with PVS 300 bar [4351 psi]
PVG 32 with PVSI 350 bar [5076 psi]
PVG 32 with PVBZ 210 bar [3046 psi]
PVG 32 with HIC aluminum 210 bar [3046 psi]
PVG 32/120 with PVS 300 bar [4351 psi]
PVG 32/120 with PVSI 350 bar [5076 psi]
PVG 32/100 with PVS 300 bar [4351 psi]
PVG 32/100 with PVSI 350 bar [5076 psi]
Torque on connection/port based on seal used
Seal Connection/port
P A/B T LS, M, LSA,
LSB, PVH,
Accu.
LX, PVS, PVSI
Sealing thread G1/2 G3/4 G1/2 G3/4 G1/2 G1/8 G1/4
With steel washer 130 N•m [1150
lbf•in]
210 N•m [1850
lbf•in]
130 N•m [1150
lbf•in]
210 N•m [1850
lbf•in]
40 N•m [350
lbf•in]
17 N•m [150
lbf•in]
40 N•m [350
lbf•in]
Service and Parts Manual
PVG 16/32/128/256
Installation
©
Danfoss | October 2018 AX284661889190en-000101 | 27

Table of Contents

Other manuals for Danfoss PVG 128

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 128 and is the answer not in the manual?

Danfoss PVG 128 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 128
CategoryControl Unit
LanguageEnglish

Related product manuals