Page #46 background image
PVE 128/256 PVE series 7 installation
PVEO Series P7 VEH/H-U/H-FLA Series 7
8 ±0.5 N•m
[70 ±4.4 lbf•in]
5 [0.2]
P006095
W
Warning
For safety reasons, the PVE actuator and interface components must be considered as one unit. Do not
try to disassemble under any circumstances.
PVG 128/256 PVE connector variants
1x4 DEUTSCH 1x6 DEUTSCH 1x4 DIN
2
3
4
1
1
2
3 4
5
6
1 2
3
4
Pin Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6
PVEO 1x4 DEUTSCH Udc_A GND GND Udc_B
1x4 DIN Udc_A Udc_B GND
PVEH
PVEH-U
1x4 DEUTSCH Us Error GND Udc
1x4 DIN Udc Us Error GND
PVEH-FLA 1x6 DEUTSCH Us Error Float GND Udc
PVG 128/256 PVE control specifications
PVEO control specifications
Control specification PVEO
Supply Voltage (Udc) Rated 12 Vdc 24 Vdc
Range 1115 Vdc 2230 Vdc
Max. ripple 5% 5%