Page #49 background imageLoading...
Page #49 background image
PVHC for PVG 128/256 installation
5 [0.2]
8 ± 0.5 N•m
[70 ± 4.4 lbf•in]
PVHC for PVG 128/256 connector
The seal in the PVHC connector and the seals for individual conductors are crucial for correctly sealing the
connector.
DEUTSCH Version
AMP Version
(B) Udc
(B) Udc
(A) Udc
(A) Udc
PVHC for PVG 128/256 technical data
Controller output current range 12 V 1 - 1500 mA
24 V 0 - 750 mA
Coil resistance 12 V 4.72 Ω ± 5%
24 V 20.8 Ω ± 5%
Pilot pressure (over tank)
*
Nominal 25 bar [363 psi]
Minimum 21 bar [305 psi]
Maximum 25 bar [363 psi]
Control pressure Range 5 - 15 bar [72.5 - 217.5 psi]
Max. tank pressure Port T Static 25 bar [363 psi]
Port T Dynamic 30 bar [435 psi]
Temperature range Ambient -30°C 80°C [-22°F 176°F]
Medium -20°C 80°C [-4°F 176°F]
Oil viscosity Operating range 12 75 mm2/s [65 347 SUS]
Minimum 4 mm
2
/s [39 SUS]
Maximum 400 mm
2
/s [2130 SUS]
Service and Parts Manual
PVG 16/32/128/256
Installation
©
Danfoss | October 2018 AX284661889190en-000101 | 49

Table of Contents

Other manuals for Danfoss PVG 128

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 128 and is the answer not in the manual?

Danfoss PVG 128 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 128
CategoryControl Unit
LanguageEnglish

Related product manuals