Description Value
Maximum tank pressure Port T Static 25 bar [363 psi]
Port T Dynamic 30 bar [435 psi]
Temperature range Ambient -30°C to 80°C [-22 to 176°F]
Medium -20°C to 80°C [-4 to 176°F]
Oil viscosity Range 12 to 75 mm2/s [65 to 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 400 mm2/s [2130 SUS]
Enclosure – Protection class DEUTSCH DT IP 67
AMP JPT IP 66
Filtering in the hydraulic system;
Max. permissible degree of
contamination
23/19/16 (ISO 4406, 1999 version)
*
Designed to be used with hydraulic activated spools
The PVHC is produced in an environment using mineral based hydraulic oil.
Service and Parts Manual