Page #132 background image
Factory Settings
PNU # Parameter description Factory setting Range
Changes
during
operation
4-Setup
Conversion
index
Data
type
001
Language English Yes No 0 5
002 Local/remote control Remote control Yes Yes 0 5
003 Local reference 000.000 Yes Yes -3 4
004 Active setup Setup 1 Yes No 0 5
005 Programming setup Active setup Yes No 0 5
006 Copying of setups No copying No No 0 5
007 LCP copy No copying No No 0 5
008 Display scaling of motor frequency 1 0.01 - 500.00 Yes Yes -2 6
009 Display line 2 Frequency [Hz] Yes Yes 0 5
010 Display line 1.1 Reference [%] Yes Yes 0 5
011 Display line 1.2 Motor current [A] Yes Yes 0 5
012 Display line 1.3 Power [kW] Yes Yes 0 5
013 Local control/configura LCP digital control/as
par.100
Yes Yes 0 5
014 Local stop Possible Yes Yes 0 5
015 Local jog Not possible Yes Yes 0 5
016 Local reversing Not possible Yes Yes 0 5
017 Local reset of trip Possible Yes Yes 0 5
018 Lock for data change Not locked Yes Yes 0 5
019 Operating state at power-up, local
control
Forced stop, use
saved ref.
Yes Yes 0 5
027 Warning readout Warning in line 1/2 Yes No 0 5
Changes during operation:
"Yes" means that the parameter can be changed,
while the frequency converter is in operation. "No"
means that the frequency converter must be stopped
before a change can be made.
4-Setup:
"Yes" means that the parameter can be programmed
individually in each of the four setups, i.e. the same
parameter can have four different data values. "No"
means that the data value will be the same in all four
setups.
Conversion index:
This number refers to a conversion figure to be used
when writing or reading by means of a frequency con-
verter.
Conversion index Conversion factor
74 0.1
2 100
1 10
0 1
-1 0.1
-2 0.01
-3 0.001
-4 0.0001
Data type:
Data type shows the type and length of the telegram.
Data type
Description
3 Integer 16
4 Integer 32
5 Unsigned 8
6 Unsigned 16
7 Unsigned 32
9Text string
VLT
®
5000 Design Guide
MG.52.B2.02 - VLT
®
is a registered Danfoss trademark 131
Factory settings

Table of Contents

Other manuals for Danfoss VLT 5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5000 Series and is the answer not in the manual?

Danfoss VLT 5000 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5000 Series
CategoryDC Drives
LanguageEnglish

Related product manuals