Last change or command is cancelled as long as the
display has not been changed.
C
a
n
c
e
l
Figure 2.9 Cancel Icon
[Info]
Displays information about a command, parameter, or
function in any display window. [Info] provides detailed
information when needed.
Exit Info mode by pressing either [Info], [Back], or [Cancel].
I
n
f
o
Figure 2.10 Info Icon
Navigation keys
The four navigation keys are used to navigate between the
different choices available in [Quick Menu], [Main Menu]
and [Alarm Log]. Press the keys to move the cursor.
[OK]
Is used for choosing a parameter marked by the cursor
and for enabling the change of a parameter.
130BT117.10
OK
Back
Info
Warn
Alarm
On
Cancel
Figure 2.11 Navigation Keys
Operation keys
For local control are placed at the bottom of the control
panel.
Figure 2.12 Operation Keys
[Hand On]
Enables control of the adjustable frequency drive via the
LCP. [Hand On] also starts the motor and it is now possible
to enter the motor speed data with the navigation keys.
The key can be selected as [1] Enable or [0] Disable via
0-40 [Hand on] Key on LCP.
The following control signals are still active when [Hand
On] is activated:
[Hand On] - [Off] - [Auto On]
Reset
Coasting stop inverse
Reversing
Set-up select lsb - Set-up select msb
Stop command from serial communication
Quick stop
DC brake
NOTICE!
External stop signals activated with control signals or a
serial bus overrides a Start command via the LCP.
[Off]
Stops the connected motor. The key can be selected as [1]
Enable or [0] Disable via 0-41 [Off] Key on LCP. If no external
stop function is selected and the [Off] key is inactive, the
motor can only be stopped by disconnecting the line
power supply.
[Auto On]
Enables the adjustable frequency drive to be controlled via
the control terminals and/or serial communication. When a
start signal is applied on the control terminals and/or the
bus, the adjustable frequency drive starts. The key can be
selected as [1] Enable or [0] Disable via 0-42 [Auto on] Key
on LCP.
NOTICE!
An active HAND-OFF-AUTO signal via the digital inputs
has higher priority than the control keys [Hand On]
[Auto On].
[Reset]
Is used for resetting the adjustable frequency drive after an
alarm (trip). It can be selected as [1] Enable or [0] Disable
via 0-43 [Reset] Key on LCP.
2.2.2
Numeric Local Control Panel (NLCP)
See the Design Guide for instructions for using the
numeric LCP.
Operator Interface and Adju...
Service Manual
24 Danfoss A/S © Rev. 2014-02-10 All rights reserved. MG94A222
22

Table of Contents

Other manuals for Danfoss VLT FC 300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 300 and is the answer not in the manual?

Danfoss VLT FC 300 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 300
CategoryDC Drives
LanguageEnglish

Related product manuals