Parameter 009, 010, 011 and 012 (Display line 1 and 2) has got 5 additional
selections:
VLT5000 VLT5000Flux
User parameter 95 [90] [90]
User parameter 96 [91] [91]
User parameter 97 [92] [92]
User parameter 98 [93] [93]
User parameter 99 [94] [94]
Parameter 115 (Slip compensation): Factory setting changed from 100% to 0%.
Factory settings changed:
From to
Parameter 200 Only clockwise 132Hz [0] Both directions 132 Hz [1]
Parameter 203 Min … Max [0] –Max … +Max [1]
Parameter 207 Power dependent 0,05 sec
Parameter 208 Power dependent 0,05 sec
Factory settings VLT5000:
Parameters 300 - 303, 305 - 308, 314 changed to: ”No operation”
[0]
Parameters 319 + 321 changed to: ”Option 0 … 20mA” [91]
Parameters 323 + 326 changed to: ”Control word bit 11/12” [33]
4 Additional selections in parameters 319+321: Option digital [90]
Option 0 … 20mA [91]
Option 4 … 20mA [92]
Option 0 … 32000 pulses [93]
Factory settings VLT5000Flux:
Changed factory settings:
Parameters 300…303, 305…308, 314 changed to “No operation” [0]
Parameters 319 + 321 changed to “Option 0 … 20mA” [90]
Parameters 323 + 326 changed to “Control word bit11/12 [33]
Parameters 341 + 355 changed to “Option digital” [90]
2 Additional selections in parameters 319 + 321: Option 0 … 20mA [90]
Option 4 … 20mA [91]
2 Additional selections in parameters 341 + 355: Option digital [90]
Option pulse output [91]
Group 7: next page