Programmable SyncPos motion controller
Programming with SyncPos
Fundamental Program Layout
Definitions: Arrays, Interrupts, User
parameters
Initializing: Setting parameters, flags and
variables
Main program loop
main:
GOTO main
Sub program area
SUBMAINPROG
SUBPROG name
RETURN
ENDPROG
Definitions
Array DIM send[12], receive[12]
Interrupt ON ERROR GOSUB errhandle
ON INT –1 GOSUB stopprog
ON PERIOD 500 GOSUB calc
ON TIME 10000 GOSUB break
User parameters
LINKAXPAR SYNCACCURACY 710
"ACCURACY [qc]" 0 100000 0
LINKGPAR 133 716 "Offset [qc]" 0
100000 0
Initializing
Parameters SET POSERR 100000000
SET 133 10000
SETVLT 205 50
Flags/variables offset = 0
sync_flag = 0
System parameters VEL 100
ACC 100
DEC 100
Main program
main:
IF (IN 3 == 1) THEN
/* Go into synchronizing mode, if input 3 = 1 */
GOSUB syncprog
ELSE
GOSUB speedprog
/* If input 3 not = 1, run in speed mode */
GOTO main
Sub programs
SUBMAINPROG:
SUBPROG syncprog
IF (sync_flag ==0) THEN
/* synchronize, if not already synchronized */
SYNCP
sync_flag = 1
ENDIF
RETURN
SUBPROG errhandle
WAITI 18 on
/* waiting for digital input 18, clear the error */
sync_flag = 0
ERRCLR
RETURN
ENDPROG
Sequential command processing
In general a command is processed to the end
before a new command is begun. This means that
for position commands the program waits until the
target position has been reached.
Exception: If NOWAIT has been set to ON.
Fundamental Command Structure
All instructions consist of: COMMAND WORD +
possible
ParameterParameter
ParameterParameter
Parameter
. .
. .
. A variable can also be used
as parameter instead of an absolute number.
Example
POSA 10000
or
pos = 10000
POSA pos
Command run times
If the command execution times are critical in an
application it is possible to measure the run times
of a command sequence under the different ope-
rating conditions using the command TIME.
Tips for Increasing Program Readability
Use of capital and small initial letters (i.e. all
commands capital letters, all variables small).
Placement of spacing between command
parts.
Place comments in your program. The com-
ments are between
/* … */ or after //…
/* Begin COMMENT End */
// Begin COMMENT End
Inadmissible is nesting comments (/*
......
......
... /*
......
......
...*/)
Use of line identification within the loop.
Programming with SyncPos

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT5000 SyncPos and is the answer not in the manual?

Danfoss VLT5000 SyncPos Specifications

General IconGeneral
BrandDanfoss
ModelVLT5000 SyncPos
CategoryController
LanguageEnglish

Related product manuals