Programmable SyncPos motion controller
MG.10.J8.02 – VLT is a registered Danfoss trade mark
168
VLT par. # Option parameter Parameter Read/Write
LCP access # and name Application program
700 GETVLT/SETVLT parameter number
Ex.: var = GETVLT 700
701 102 PRGPAR
702 11 KPROP
703 12 KDER
704 13 KINT GET/SET parameter name
705 21 KILIM Ex.: var = GET KPROP
706 35 BANDWIDTH
707 36 FFVEL
708 37 FFACC
709 65 SYNCVFTIME
710-779 130 – 229 GET/SET parameter number
Ex.: var = GET 131
780 GETVLT/SETVLT parameter number
781 Program ID Ex.: var = GETVLT 780
795-799 130 – 229 GET/SET parameter number
Ex.: var = GET 132
Group 7:
NB!
In general it is very important to optimize the
VLT parameters to the motor, i.e. by using
AMA, in order to obtain a good control behavior.
Parameter 205
Parameter 205, maximum reference must be set in
accordance with maximum velocity (option para-
meter #1) before the controller parameters are
optimized.
Parameter Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT5000 SyncPos and is the answer not in the manual?

Danfoss VLT5000 SyncPos Specifications

General IconGeneral
BrandDanfoss
ModelVLT5000 SyncPos
CategoryController
LanguageEnglish

Related product manuals