SD260L/SD360/SD460 Installation and Administrator’s Guide 73
LaminateType
Use the LaminateType options to specify settings for the overlay materials used in the laminating
system.
Description
Default
Value
Current Value
(unit) Allowed Range
1) DatabaseVersion 1 13 [1 – 999]
2) ExclusiveOverlayInL1 Disabled
3) ExclusiveOverlayInL2 Disabled
4) OverlayDisplayed Name 0.5_mil_Clear_DG
5) OverlayLoadedInL1 Name 0.5_mil_Clear_DG
6) OverlayLoadedInL2 Name Clear_Topcoat
OverlayPartNumber 0 509065
OverlaySpeed 160 160 [100 – 250]
OverlaySpeed AdjustmentL1 0 0 [-40 – 40]
OverlaySpeed AdjustmentL2 0 0 [-40 – 40]
OverlayTemp 160 175 [100 – 200]
OverlayTemp AdjustmentL1 0 15 [-20 – 40]
OverlayTemp AdjustmentL2 0 0 [-20 – 40]
UserOverlay1Name None
UserOverlay2Name None
UserOver3Name None
UserOverlay4Name None