ENTER/EXIT PROGRAMMING MODE 1D SYMBOLOGIES
140
POWERSCAN™ PD/PM96XX
Code 32 Start/Stop Character Transmission
Enable this option to enable/disable transmission of Code 32 start and stop characters.
CODE 39 CIP HR (FRENCH PHARMACEUTICAL)
The following options apply to the Code 39 CIP HR symbology.
Code 39 CIP HR Enable/Disable
Enables/Disables ability of the reader to decode Code 39 CIP HR labels.
$CP3SS00
Code 32 Start/Stop Character Transmission
= Don’t Transmit
Code 32 Start/Stop Character Transmission
= Transmit
$CP3SS01
$CCCEN00
Code 39 CIP HR = Disable
Code 39 CIP HR = Enable
$CCCEN01