PLESSEY ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
191
Plessey Set Length 1
This feature specifies one of the bar code lengths for "Plessey Length Control" on page
190
. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed
length if in Fixed Length Mode. The length includes the bar code’s check and data char-
acters.
The length can be set from 1 to 50 characters. See "
Set Length 1" on page 301 for more
detailed programming instructions.
Plessey Set Length 2
This feature specifies one of the bar code lengths for "Plessey Length Control" on page
190
. Length 2 is the maximum label length if in Variable Length Mode, or the second
fixed length if in Fixed Length Mode. The length includes the bar code’s check and data
characters.
Length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length
(only one fixed length). See "
Set Length 2" on page 302 for more detailed programming
instructions.
Select Plessey Length 1 Setting
$CPLL1
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 1 = 01 (one character)
Select Plessey Length 2 Setting
$CPLL2
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 2 = 50 (50 characters)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PM96 Series and is the answer not in the manual?

Datalogic PowerScan PM96 Series Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PM96 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals