COMPRESSED 2 OF 5 ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
159
Compressed 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for "Compressed 2 of 5 Length Control"
on page 158
. Length 1 is the minimum label length if in Variable Length Mode, or the
first fixed length if in Fixed Length Mode. The length includes the bar code’s check and
data characters.
The length can be set from 1 to 50 characters. See "
Set Length 1" on page 301 for more
detailed programming instructions.
Compressed 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for "Compressed 2 of 5 Length Control"
on page 158
. Length 2 is the maximum label length if in Variable Length Mode, or the
second fixed length if in Fixed Length Mode. The length includes the bar code’s check
and data characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this
length (only one fixed length). See "
Set Length 2" on page 302 for more detailed pro-
gramming instructions.
Select Compressed 2 of 5 Length 1 Setting
$CC2L1
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 1 = 01 (one character)
Select Compressed 2 of 5 Set Length 2 Setting
$CC2L2
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 2 = 50 (50 characters)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PM96 Series and is the answer not in the manual?

Datalogic PowerScan PM96 Series Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PM96 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals