Symbologies
6-42 QuickScan
®
QS6500/QS6500 BT
RSS-14
The following options apply to the RSS-14 symbology.
Disable/Enable RSS-14
When this feature is disabled, the imager will not read RSS-14 bar codes.
Checksum Transmission
Enable this option to transmit the checksum along with RSS-14 bar
code data.
UCC/EAN 128 Emulation
When enabled, RSS-14 bar codes will be translated to the UCC/EAN
128 label data format.

Table of Contents

Other manuals for Datalogic QuickScan QS6500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan QS6500 and is the answer not in the manual?

Datalogic QuickScan QS6500 Specifications

General IconGeneral
Scan speed450 sec/page
Tilt angle range-60 - 60 °
Maximum scan area610 mm
Decoding standards- 1D - Code 16K - EAN/JAN - GS1 DataBar - PDF Models - GS1 DataBar Expanded Stacked - GS1 DataBar Stacked - GS1 DataBar Stacked Omnidirectional - MicroPDF417 - PDF417 - UPC A/E
Dimensions (WxDxH)165 x 74 x 99 mm
Cable length2.44 m
Standard interfacesKeyboard wedge
Input voltage4.5 - 14 V
Power consumption300 mA
CertificationRoHS
Product colorBlack
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Weight181.4 g