Troubleshooting Your System 121
Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the
components inside the system. Before performing any procedure, see your Product Information Guide for
complete information about safety precautions, working inside the computer and protecting against electrostatic
discharge.
1
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2
Open the system. See "Opening and Closing the System" on page 55.
3
Remove all expansion cards installed in the system. See "Removing an Expansion Card" on page 74.
4
Let the system dry thoroughly for at least 24 hours.
5
Close the system. See "Opening and Closing the System" on page 55.
6
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the system does not start properly, see "Getting Help" on page 147.
7
If the system starts properly, shut down the system and reinstall all of the expansion cards that you
removed. See "Installing an Expansion Card" on page 72.
8
Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" on page 135.
If the tests fail, see "Getting Help" on page 147.
Troubleshooting a Damaged System
Problem
System was dropped or damaged.
Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the
components inside the system. Before performing any procedure, see your Product Information Guide for
complete information about safety precautions, working inside the computer and protecting against electrostatic
discharge.
1
Open the system. See "Opening and Closing the System" on page 55.
2
Ensure that the following components are properly installed:
Expansion cards and risers
Power supplies
•Fans
Processors and heat sinks
Memory modules
Drive-carrier connections to the SAS/SATA backplane board, if applicable
3
Ensure that all cables are properly connected.

Table of Contents

Other manuals for Dell PowerEdge 2970

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge 2970 and is the answer not in the manual?

Dell PowerEdge 2970 Specifications

General IconGeneral
BrandDell
ModelPowerEdge 2970
CategoryServer
LanguageEnglish

Related product manuals