Troubleshooting 147
Replace Member Errors
Table 9-6 describes issues related to the Replace Member feature.
NOTE: For more information about the Replace Member features, see
"Using
Replace Member and Revertible Hot Spares" on page 35
.
Table 9-6. Replace Member Operation Errors
Issue Corrective Action
The source disk fails
during the Replace
Member operation.
If the source data is available from other disks in the virtual
disk, the rebuild begins automatically on the target disk, using
the data from the other disks.
Target disk fails If the target disk fails, the Replace Member operation aborts.
Other disks fail If the target disk fails and the Replace Member operation
aborts but the source data is still available, then the Replace
Member operation continues as Replace Member.
PERC7.2_UG.book Page 147 Thursday, March 3, 2011 2:14 PM