Chapter 7 Servo Parameters|ASDA-AB Series
7-50
Revision January 2009
P1 - 62
COKT
Delay Time of Internal Position Command
Completed Output Signal
Communication Addr.: 013EH
Default: 0 Related Section:
Applicable Control Mode: Pr DO CMDOK(12) in Table 7.B
Unit: ms
Range: 0 ~ 200
Settings:
This parameter is used to delay the output time of digital output, CMDOK (Internal position
command completed output) when the servo drive has detected the internal position command
has been completed.
If this parameter is set to 0, when DO ZSPD=1, the internal position command which is triggered
by DI CTRG will be accepted. If this parameter is not set to 0, when DO CMDOK=1, the internal
position command which is triggered by DI CTRG will be accepted.
Please see DO CMDOK(12) in Table 7.B for explanation.
P1 - 63
Reserved Communication Addr.: 013FH
P1 - 64
Reserved Communication Addr.: 0140H

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics AC Servo Drive ASDA-AB and is the answer not in the manual?

Delta Electronics AC Servo Drive ASDA-AB Specifications

General IconGeneral
BrandDelta Electronics
ModelAC Servo Drive ASDA-AB
CategoryDC Drives
LanguageEnglish

Related product manuals