Chapter 7 Servo Parameters|ASDA-AB Series
7-86
Revision January 2009
P4 - 16 COF2 Current Detector Drift Adjustment (V2 phase) Communication Addr.: 0410H
Default: Factory setting Related Section: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: 0~32767
Settings:
Please see P4-15 for explanation.
P4 - 17 COF3 Current Detector Drift Adjustment (W1 phase) Communication Addr.: 0411H
Default: Factory setting Related Section: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: 0~32767
Settings:
Please see P4-15 for explanation.
P4 - 18 COF4 Current Detector Drift Adjustment (W2 phase) Communication Addr.: 0412H
Default: Factory setting Related Section: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: 0~32767
Settings:
Please see P4-15 for explanation.
P4 - 19
TIGB IGBT NTC Calibration Communication Addr.: 0413H
Default: Factory setting Related Section: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: 1~7
Settings:
This parameter cannot be reset.
When executing this auto adjustment, ensure to cool the servo drive to 25
o
C.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics AC Servo Drive ASDA-AB and is the answer not in the manual?

Delta Electronics AC Servo Drive ASDA-AB Specifications

General IconGeneral
BrandDelta Electronics
ModelAC Servo Drive ASDA-AB
CategoryDC Drives
LanguageEnglish

Related product manuals